Panels in series
Module and series count · panels
Allowed range: 1 to 1000
Compare a proposed series string against entered cold Voc and hot Vmp limits.
Open this toolCold conditions can raise a panel string's open circuit voltage, while hot cells can reduce operating voltage.
Enter module coefficients and site temperature assumptions, then compare corrected string values with the entered inverter limits.
Module and series count · panels
Allowed range: 1 to 1000
Module and series count · V
Allowed range: 0.01 to 1000
Module and series count · V
Allowed range: 0.01 to 1000
Temperature correction · ×
Allowed range: 1 to 3
Temperature correction · ×
Allowed range: 1 to 3
Use the Vmp coefficient, independently of Voc.
Temperature correction · ×
Allowed range: 0.01 to 1
Inverter voltage limits · V
Allowed range: 0.01 to 10000
Inverter voltage limits · V
Allowed range: 0.01 to 10000
Inverter voltage limits · V
Allowed range: 0.01 to 10000
Cold and hot checks stay separate so a comfortable operating voltage does not hide excessive maximum voltage.
Corrections must come from module coefficients and site temperatures. Equality with the absolute Voc limit is flagged with zero headroom. Current, startup voltage, string fusing and all equipment limits still need review.
Corrections must come from module coefficients and site temperatures. Equality with the absolute Voc limit is flagged with zero headroom. Current, startup voltage, string fusing and all equipment limits still need review.
No. Equality leaves zero headroom and is flagged. Appropriate equipment margins need design review.
Check Panels in series, Module Voc at reference, Module Vmp at reference and Cold Voc multiplier. Use the exact units shown beside the controls and replace any example values with your own inputs.